Duct air heaters

The www.el-vent.com™ range offers one of the largest selections of ducted heaters in Baltic countries.
The wide range of electric duct heaters allows you to adapt the unit to even the most demanding ventilation or heat recovery system.
The heater can be operated in the preheating (0...+30) or heating (-30...0) ranges - the heater will automatically switch on when the temperature drops below the set limit.
We will briefly describe each series to make it easier for you to understand how the heater can be selected and adapted to your system:
  • HDE - standard heaters without automation, made in Poland
  • EHC - standard heaters without automation (all EHC series heaters are made in Lithuania)
  • EHC SI - internal temperature control with one temperature sensor, the sensor is mounted in the heater's outlet air duct, the temperature setting knob is mounted on the heater body. A ducted thermosensor with 2 m cable is included. The heater automatically switches on when the temperature drops below the set point
  • EHC SE - external temperature setting with one temperature sensor, sensor mounted in the heater outlet air duct, temperature setting unit RES001 ordered separately, room mounted (potentiometer resistance 10K). The heater automatically switches on when the temperature drops below the set limit
  • EHC CE - external control signal 0-10VDC, the control signal is fed from another controller (e.g. recuperator). The heater automatically switches on when it receives a signal from another device
  • EHC FC - flow and pressure control. The heater automatically switches on when the system is pressurised (e.g. from a fan or a recuperator switched on)
  • EHC CE/FC - external control signal 0-10VDC, control signal from another controller, and flow and pressure control. The heater automatically switches on when both conditions occur, i.e. when a signal is received from the other unit and when the system is pressurised
  • EHC SE/FC - external temperature control with one temperature sensor, sensor mounted in the heater's outlet air duct, temperature set point RES001 ordered separately, room mounted (potentiometer resistance 10K), and flow and pressure control. A duct thermosensor with 2 m cable is included. The heater automatically switches on when both conditions occur, i.e. the temperature drops below the set point and the system is pressurised
  • EHC SI/FC - internal temperature control with one temperature sensor, the sensor is mounted in the heater outlet air duct, a temperature control knob mounted on the heater body, and flow and pressure control. A ducted thermosensor with 2 m cable is included. The heater automatically switches on when both conditions occur, i.e. the temperature falls below the set point and the system is pressurised
The heaters below are made to special order:
  • EHC K - standard version without integrated control, with contactor
  • EHC CE/K - external control signal 0-10VDC, control signal from another controller, with contactor
  • EHC SE/K - external temperature control with one temperature sensor, sensor mounted in the heater's outlet air duct, temperature control unit mounted in the room (potentiometer resistance - 10K), with contactor
  • EHC SI/K - indoor temperature control with one temperature sensor, sensor mounted in the heater outlet air duct, temperature setting knob mounted on the heater body, with contactor
  • EHC FC/K - flow and pressure control, with contactor
  • EHC CE/FC/K - external control signal 0-10VDC, control signal from another controller, and flow and pressure control, with contactor
  • EHC SE/FC/K - external temperature control with one temperature sensor, sensor mounted in the heater outlet air duct, temperature control unit mounted in the room (potentiometer resistance - 10K), flow and pressure control, with contactor
  • EHC SI/FC/K - internal temperature control with one temperature sensor, sensor mounted in the heater outlet air duct, temperature setting knob mounted on the heater body, flow and pressure control, with contactor
Also available in the range of water-cooled heaters:
  • HDW - operating temperature from -25 to 100 °C
  • DHCW - operating temperature from -21 to 130 °C with anti-condensation coating and drainage
No matter where you are - in Riga, Tallin, Helsinki or Oslo - we deliver to your door at the best price. You are also welcome to visit our branded store in Kaunas or our headquarters in Viečiūnai and buy the products you need here.