Price:
Price / SUPRA: |
Select
|
Price / SUPRA-FIX for wall mounting: |
Select
|
EU shipping 14 working days, non EU 21 working days
Ask a question about this item
Ask a question about this item
SUPRA STANDARD 25 - access panels for 25 mm plasterboard in standard dimensions
A - outer frame fixed to plasterboard
B - inner frame - a door that can be removed when opened
C - safety holders which allow the door to open smoothly
D - galvanised steel fixing angles
E - self-tapping screws for fixing the door frame to the plasterboard
Code
|
A
|
B
|
C | D | E |
door dimension | dimension of opening in plasterboard | plasterboard thickness | |||
SUPRA2020/25 | 200 | 200 | 201 | 201 | 25 |
SUPRA3030/25 | 300 | 300 | 301 | 301 | 25 |
SUPRA4040/25 | 400 | 400 | 401 | 401 | 25 |
SUPRA5050/25 | 500 | 500 | 501 | 501 | 25 |
SUPRA6060/25 | 600 | 600 | 601 | 601 | 25 |
1. SUPRA STANDARD 25 access panels is suitable only for wall mounting, latches must be at the top
2. it is forbidden to glue tiles on all SUPRA STANDARD 25 panels
3. fix the panel frame with 15-20 mm self-tapping screws
4. the recommended distance of the plasterboard wall fixing profile from the boundary of the opening is 30 - 100 mm
5. putty the door when removed from the frame and the frame already installed in the opening
6. paint the door after it has been removed from the frame and the frame after it has been installed and painted in the opening
You might also like: