Centrifugal bathroom fans with EC motors ELIX EC 2V
- EC 2V - the fan runs continuously at low speed (one of two low speeds can be set at the time of installation), switching on the switch activates the maximum speed, switching off the switch allows the fan to continue running at low speed
- EC 2V DT - with timer: the fan runs continuously at low speed (one of two low speeds can be set at the time of installation), when the switch is turned on the maximum speed is activated and when turned off the fan will run for the time period set by the timer (from 2 minutes up to 30 minutes) and then fan switches back to the minimum speed. To avoid additional noises during the night, there is a possibility to delay the fan at maximum speed for 2 minutes during the night, i.e. if you are in the WC for less than 2 minutes the fan will not start at maximum speed, if you are in the WC for more than 2 minutes the fan will start at maximum speed and will operate for the time period set by the timer and then will switch back to the minimum speed.
- EC 2V HDT - with timer and humidity sensor: the fan runs continuously at low speed (one of two low speeds can be set at the time of installation), when the switch is turned on it will run at maximum speed, and when turned off it will run for the time period set by the timer (2 to 30 min.) and then fan switches back to minimum speed. If the humidity level rises above the set point (control range from 40% to 90%), the fan will automatically switches itself to maximum speed and operate for a timer-set period of time. If the humidity level drops below the set point then the fan will switch to minimum speed, if the humidity level remains above the set point the fan will run at maximum speed for one more cycle. The number of cycles is unlimited until the humidity level falls below the set point. To avoid additional noises during the night, it is possible to delay the fan's maximum speed for 2 minutes during the night, i.e. if you are in the WC for less than 2 minutes, the fan will not run at maximum speed, if you are in the WC for more than 2 minutes, the fan will run at maximum speed for the time set by the timer and then switch back to minimum speed.
The retractable filter can be washed under the tap with plain soap
Code | A | B | C | D | ØE | F |
ELIX 100 EC 2V | 180 | 180 | 116 | 87 | 99 | 29 |
Code | Motor | m³/h | l/s | Pa | W | dB(A)* | |
kg | |||||||
ELIX 100 EC 2V | EC | 100 / 46 / 32 | 28 / 13 / 9 | 200 / 44 / 23 | 15 / 2.4 / 1.6 | 37 / 18 / 16 | 2.6 |
ELIX 100 EC 2V DT | EC | 100 / 46 / 32 | 28 / 13 / 9 | 200 / 44 / 23 | 15 / 2.4 / 1.6 | 37 / 18 / 16 | 2.6 |
ELIX 100 EC 2V HDT | EC | 100 / 46 / 32 | 28 / 13 / 9 | 200 / 44 / 23 | 15 / 2.4 / 1.6 | 37 / 18 / 16 | 2.6 |
*LpA, measured at 3 m in open field 230V-50 Hz