- ELPREX centrifugal fans for direct extraction of air from kitchens, baths, other very humid areas
- the centrifugal impeller generates high pressures and blows extremely high volumes of air through Ø100 mm ducts and more complex duct systems up to 15 m long
- the decentralised Ø100 mm air outlet allows the fan to be installed even in hard-to-reach areas
- the fan can be installed in the ceiling or in the wall, i.e. recessed into the wall or ceiling, then kit 2SV0110 must be ordered separately
- suitable for ceiling or wall installation
- motors with ball bearings
- with non-return valve
- with a durable, easy-to-wash protective filter
- the filter can be washed under the crane with plain soap
- models:
- BASE - basic
- PC - with cord
- T - with timer, timer principle: the fan will always run when switched on and when switched off it will operate for a time period set by the timer (from 3 to 25 min.) and then switch itself off
- CMT - comfotaimer (when the switch is switched on it starts to run at maximum speed, when the switch is switched off it runs at a low speed for a timed period of 3 to 25 min and switches off). The low-speed start function saves up to 64% energy compared to the standard version of the timer. The low speed ensures quieter fan operation and energy savings, while maintaining sufficient air exhaust efficiency. The version is particularly suitable for hotels, hospitals, private homes and all applications where maximum comfort is required
- MHY SMART - with intelligent humidity sensor (depending on the humidity level, the speed is increased automatically, and the speed decreases automatically as the humidity level decreases)
- MHT - with humidity sensor and timer: the fan will always run when switched on and when switched off it will affect the timer for a set period of time (from 3 to 25 min.) and will switch off by itself, when the humidity level in the room rises to a set level it will automatically switch on the timer for a time set by the timer, or until the humidity level drops below the set level, the humidity sensor is adjustable from 40% to 80%
- 2 V - two-speed (fan runs continuously at low speed, switching on the switch activates maximum speed, switching back to low speed when switched off)
- maximum ambient temperature 40 °C
- special gasket included to prevent moisture ingress and vibration
- complies with ErP Directive 2009/125/EC and EU Regulation 1253/2014
- made in Italy
- 5 years warranty
- installation examples:
Includes non-return valve
Air is drawn in from all sides by means of a cover
Brand:
ELICENT
Code |
Motor |
m³/h |
l/s |
Pa |
W |
dB(A)* |
kg |
ELPREX |
AC |
221 |
61 |
208 |
29 |
41 |
2.8 |
*LpA, measured at 3 m in open field 230V-50 Hz
Speed controllers (more precise control with a transformer speed controller):
ELPREX 100 BASE |
electronic EMTY05 - 0.5 A |
5 step, transformer RVS - 0.5 A |
|
|
Pressure loss curves